ID: ESX400-201002401-BG Impact: Critical Release date: 2010-03-03 Products: esx 4.0.0 Updates vmkernel64,vmx,hostd etc

This patch provides support and fixes the following issues:

  • On some systems under heavy networking and processor load (large number of virtual machines), some NIC drivers might randomly attempt to reset the device and fail.
    The VMkernel logs generate the following messages every second:
    Oct 13 05:19:19 vmkernel: 0:09:22:33.216 cpu2:4390)WARNING: LinNet: netdev_watchdog: NETDEV WATCHDOG: vmnic1: transmit timed out
    Oct 13 05:19:20 vmkernel: 0:09:22:34.218 cpu8:4395)WARNING: LinNet: netdev_watchdog: NETDEV WATCHDOG: vmnic1: transmit timed out
  • ESX hosts do not display the proper status of the NFS datastore after recovering from a connectivity loss.
    Symptom: In vCenter Server, the NFS datastore is displayed as inactive.
  • When using NPIV, if the LUN on the physical HBA path is not same as the LUN on the virtual port (VPORT) path, though the LUNID:TARGETID pairs are same, then I/O might be directed to the wrong LUN causing a possible data corruption. Refer KB 1015290 for more information.
    Symptom: If NPIV is not configured properly, I/O might be directed to the wrong disk.
  • On Fujitsu systems, the OEM-IPMI-Command-Handler that lists the available OEM IPMI commands do not work as intended. No custom OEM IPMI commands are listed, though they were initialized correctly by the OEM. After applying this fix, running the VMware_IPMIOEMExtensionService and VMware_IPMIOEMExtensionServiceImpl objects displays the supported commands as listed in the command files.
  • Provides prebuilt kernel module drivers for Ubuntu 9.10 guest operating systems.
  • Adds support for upstreamed kernel PVSCSI and vmxnet3 modules.
  • Provides a change to the maintenance mode requirement during Cisco Nexus 1000V software upgrade. After installing this patch if you perform Cisco Nexus 1000V software upgrade, the ESX host goes into maintenance mode during the VEM upgrade.
  • In certain race conditions, freeing journal blocks from VMFS filesystems might fail. The WARNING: J3: 1625: Error freeing journal block (returned 0) <FB 428659> for 497dd872-042e6e6b-942e-00215a4f87bb: Lock was not free error is written to the VMware logs.
  • Changing the resolution of the guest operating system over a PCoIP connection (desktops managed by View 4.0) might cause the virtual machine to stop responding.
    Symptoms: The following symptoms might be visible:

    • When you try to connect to the virtual machine through a vCenter Server console, a black screen appears with the Unable to connect to MKS: vmx connection handshake failed for vmfs {VM Path} message.
    • Performance graphs for CPU and memory usage in vCenter Server drop to 0.
    • Virtual machines cannot be powered off or restarted.

ID: ESX400-201002402-BG Impact: Critical Release date: 2010-03-03 Products: esx 4.0.0 Updates initscripts

This patch fixes an issue where pressing Ctrl+Alt+Delete on service console causes ESX 4.0 hosts to reboot.

ID: ESX400-201002404-SG Impact: HostSecurity Release date: 2010-03-03 Products: esx 4.0.0 Updates glib2

The service console package for GLib2 is updated to version glib2-2.12.3-4.el5_3.1. This GLib update fixes an issue where the functions inside GLib incorrectly allows multiple integer overflows leading to heap-based buffer overflows in GLib’s Base64 encoding and decoding functions. This might allow an attacker to possibly execute arbitrary code while a user is running the application. The Common Vulnerabilities and Exposures Project (cve.mitre.org) has assigned the name CVE-2008-4316 to this issue.

ID: ESX400-201002405-BG Impact: Critical Release date: 2010-03-03 Products: esx 4.0.0 Updates megaraid-sas

This patch fixes an issue where some applications do not receive events even after registering for Asynchronous Event Notifications (AEN). This issue occurs when multiple applications register for AENs.

ID: ESX400-201002406-SG Impact: HostSecurity Release date: 2010-03-03 Products: esx 4.0.0 Updates newt

The service console package for Newt library is updated to version newt-0.52.2-12.el5_4.1. This security update of Newt library fixes an issue where an attacker might cause a denial of service or possibly execute arbitrary code with the privileges of a user who is running applications using the Newt library. The Common Vulnerabilities and Exposures Project (cve.mitre.org) has assigned the name CVE-2009-2905 to this issue.

ID: ESX400-201002407-SG Impact: HostSecurity Release date: 2010-03-03 Products: esx 4.0.0 Updates nfs-utils

The service console package for nfs-utils is updated to version nfs-utils-1.0.9-42.el5. This security update of nfs-utils fixes an issue that might permit a remote attacker to bypass an intended access restriction. The Common Vulnerabilities and Exposures Project (cve.mitre.org) has assigned the name CVE-2008-4552 to this issue.

ID: ESX400-201002408-BG Impact: Critical Release date: 2010-03-03 Products: esx 4.0.0 Updates Enic driver

In scenarios where Pass Thru Switching (PTS) is in effect, if virtual machines are powered on, the network interface might not come up. In PTS mode, when the network interface is brought up, PTS figures the MTU from the network. There is a race in this scenario, where the enic driver might incorrectly indicate that the driver fails. This issue might occur frequently on a CISCO UCS system. This patch fixes the issue.

ID: ESXi400-201002401-BG Impact: Critical Release date: 2010-03-03 Products: embeddedEsx 4.0.0 Updates Firmware

This patch provides support and fixes the following issues:

  • On some systems under heavy networking and processor load (large number of virtual machines), some NIC drivers might randomly attempt to reset the device and fail.
    The VMkernel logs generate the following messages every second:
    Oct 13 05:19:19 vmkernel: 0:09:22:33.216 cpu2:4390)WARNING: LinNet: netdev_watchdog: NETDEV WATCHDOG: vmnic1: transmit timed out
    Oct 13 05:19:20 vmkernel: 0:09:22:34.218 cpu8:4395)WARNING: LinNet: netdev_watchdog: NETDEV WATCHDOG: vmnic1: transmit timed out
  • ESX hosts do not display the proper status of the NFS datastore after recovering from a connectivity loss.
    Symptom: In vCenter Server, the NFS datastore is displayed as inactive.
  • When using NPIV, if the LUN on the physical HBA path is not same as the LUN on the virtual port (VPORT) path, though the LUNID:TARGETID pairs are same, then I/O might be directed to the wrong LUN causing a possible data corruption. Refer KB 1015290 for more information.
    Symptom: If NPIV is not configured properly, I/O might be directed to the wrong disk.
  • On Fujitsu systems, the OEM-IPMI-Command-Handler that lists the available OEM IPMI commands do not work as intended. No custom OEM IPMI commands are listed, though they were initialized correctly by the OEM. After applying this fix, running the VMware_IPMIOEMExtensionService and VMware_IPMIOEMExtensionServiceImpl objects displays the supported commands as listed in the command files.
  • Provides prebuilt kernel module drivers for Ubuntu 9.10 guest operating systems.
  • Adds support for upstreamed kernel PVSCSI and vmxnet3 modules.
  • Provides a change to the maintenance mode requirement during Cisco Nexus 1000V software upgrade. After installing this patch if you perform Cisco Nexus 1000V software upgrade, the ESX host goes into maintenance mode during the VEM upgrade.
  • In certain race conditions, freeing journal blocks from VMFS filesystems might fail. The WARNING: J3: 1625: Error freeing journal block (returned 0) <FB 428659> for 497dd872-042e6e6b-942e-00215a4f87bb: Lock was not free error is written to the VMware logs.
  • Changing the resolution of the guest operating system over a PCoIP connection (desktops managed by View 4.0) might cause the virtual machine to stop responding.
    Symptoms: The following symptoms might be visible:

    • When you try to connect to the virtual machine through a vCenter Server console, a black screen appears with the Unable to connect to MKS: vmx connection handshake failed for vmfs {VM Path} message.
    • Performance graphs for CPU and memory usage in vCenter Server drop to 0.
    • Virtual machines cannot be powered off or restarted.

ID: ESXi400-201002402-BG Impact: Critical Release date: 2010-03-03 Products: embeddedEsx 4.0.0 Updates VMware Tools

This patch fixes an issue where pressing Ctrl+Alt+Delete on service console causes ESX 4.0 hosts to reboot.

ID: VEM400-201002001-BG Impact: HostGeneral Release date: 2010-03-03 Products: embeddedEsx 4.0.0, esx 4.0.0 Cisco Nexus 1000V VEM

ID: VEM400-201002011-BG Impact: HostGeneral Release date: 2010-03-03 Products: embeddedEsx 4.0.0, esx 4.0.0 Cisco Nexus 1000V VEM